NFRC Codes         

Detailed Product Ratings

   
   
GENERAL INFORMATION
Manufacturer: Steel Traditions LLC
Series Name: Classic Series Steel Fixed
Operator Type: FIXD
Air Leakage: ≤ 0.3
Ventilation Rating (Standard Screen):
Ventilation Rating (Enhanced Screen):


RATINGS INFORMATION (Found 1208 Products)
<< First   < Previous   Next >   Last>>
CPD #Manufacturer Product CodeU-factorSHGCVTCondensation ResistanceProduct Description
STT-M-5-00001-00001 SunGuard SNX50 4mm_375_ARG_CL 4mm_375_ARG_SunGuard SNX50 4mm0.320.170.24 17 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , Fill 2: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00002-00001 LowE 366 3mm_655_ARG_i89 3mm0.350.240.56 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00002-00002 LowE 366 3mm_625_ARG_i89 3mm0.350.240.56 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00002-00003 LowE 366 5mm_655_ARG_i89 5mm0.350.240.55 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00002-00004 LowE 366 3mm_530_ARG_i89 3mm0.350.250.56 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00002-00005 LowE 366 5mm_530_ARG_i89 5mm0.350.240.55 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00002-00006 LowE 366 5mm_625_ARG_i89 5mm0.350.240.55 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00003-00001 LowE 366 3mm_500_ARG_i89 3mm0.350.250.56 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00003-00002 LowE 366 6mm_500_ARG_i89 6mm0.350.240.54 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00003-00003 LowE 366 6mm_500_ARG_i89 6mm0.350.240.54 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00003-00004 LowE 366 5mm_500_ARG_i89 5mm0.350.240.55 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00004-00001 LowE 366 3mm_530_ARG_CL 3mm0.400.250.57 16 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00004-00002 LowE 366 5mm_530_ARG_CL 5mm0.400.250.56 16 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00005-00001 LowE 366 3mm_655_ARG_CL 3mm0.400.250.57 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00005-00002 LowE 366 3mm_625_ARG_CL 3mm0.400.250.57 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00005-00003 LowE 366 5mm_625_ARG_CL 5mm0.400.250.56 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00005-00004 LowE 366 5mm_655_ARG_CL 5mm0.400.250.56 15 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00006-00001 LowE 366 3mm_500_ARG_CL 3mm0.400.250.57 16 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00006-00002 LowE 366 6mm_500_ARG_CL 6mm0.400.250.55 16 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00006-00003 LowE 366 5mm_500_ARG_CL 5mm0.400.250.56 16 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00007-00001 SunGuard SNX 51/23 6mm_500_ARG_CL 6mm0.390.160.29 16 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00008-00001 Climaguard 70/36 3mm_500_ARG_CL 3mm0.400.350.62 16 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00008-00002 Climaguard 70/36 5mm_500_ARG_CL 5mm0.400.340.61 16 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00008-00003 Climaguard 62/27 3mm_500_ARG_CL 3mm0.400.240.54 16 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
STT-M-5-00008-00004 Climaguard 62/27 6mm_500_ARG_CL 6mm0.400.240.52 16 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
12345678910...>>
Key:
Click the colum headers to sort the data acording to the column header.
A dash “-” in a rating column (SHGC / VT) indicates that there are no NFRC certified values for that individual product.
 

Copyright ©  National Fenestration Rating Council Incorporated ("NFRC") All rights reserved. NFRC's CMA data is protected by copyright. By accessing and downloading NFRC data from this webpage, the user agrees to abide by the Terms of Use.

The website is optimized for current browsers.

 

DISCLAIMER OF LIABILITY:
In no event shall the NFRC be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or any other loss) arising out of the use of this website or the information obtained from it, whether incidental or consequential. This provision shall apply even if the NFRC has been advised of the possibility of such damages.