CPD #Manufacturer Product CodeU-factorSHGCVTCondensation ResistanceProduct Description
STT-M-1-00001-00001 CL 6.7mm Lami0.970.720.78 14 Steel (Non thermally-broken)/Not Applicable, CL, No Grid
STT-M-1-00002-00001 CL 6.7mm Lami1.010.580.63 14  
STT-M-1-00003-00001 CL 10mm Lami0.960.690.77 15 Steel (Non thermally-broken)/Not Applicable, CL, No Grid
STT-M-1-00004-00001 CL 10mm Lami1.000.560.62 15  
STT-M-1-00005-00001 CL 3mm_530_AIR_CL 3mm0.530.700.72 36 Steel (Non thermally-broken)/Not Applicable, Fill 1: AIR(100) , CL, No Grid
STT-M-1-00006-00001 Starphire 3mm_530_AIR_Starphire 3mm0.530.740.74 36 Steel (Non thermally-broken)/Not Applicable, Fill 1: AIR(100) , CL, No Grid
STT-M-1-00007-00001 LowE 366 3mm_530_AIR_CL 3mm0.380.250.57 38 Steel (Non thermally-broken)/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
STT-M-1-00008-00001 LowE 366 3mm_530_AIR_i89 3mm0.330.240.56 38 Steel (Non thermally-broken)/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
STT-M-1-00009-00001 Climaguard 70/36 3mm_530_AIR_CL 3mm0.380.350.62 38 Steel (Non thermally-broken)/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
STT-M-1-00010-00001 Climaguard 62/27 3mm_530_AIR_CL 3mm0.380.260.54 38 Steel (Non thermally-broken)/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
STT-M-1-00011-00001 CL 3mm_530_AIR_CL 3mm0.850.630.65 27 Steel (Non thermally-broken)/Not Applicable, Fill 1: AIR(100) , CL, Grid
STT-M-1-00012-00001 Starphire 3mm_530_AIR_Starphire 3mm0.850.670.66 27 Steel (Non thermally-broken)/Not Applicable, Fill 1: AIR(100) , CL, Grid
STT-M-1-00013-00001 LowE 366 3mm_530_AIR_CL 3mm0.800.230.51 28 Steel (Non thermally-broken)/Not Applicable, Fill 1: AIR(100) , LowE, CL, Grid
STT-M-1-00014-00001 LowE 366 3mm_530_AIR_i89 3mm0.780.220.50 27 Steel (Non thermally-broken)/Not Applicable, Fill 1: AIR(100) , LowE, CL, Grid
STT-M-1-00015-00001 Climaguard 70/36 3mm_530_AIR_CL 3mm0.800.310.55 28 Steel (Non thermally-broken)/Not Applicable, Fill 1: AIR(100) , LowE, CL, Grid
STT-M-1-00016-00001 Climaguard 62/27 3mm_530_AIR_CL 3mm0.800.230.49 28 Steel (Non thermally-broken)/Not Applicable, Fill 1: AIR(100) , LowE, CL, Grid
STT-M-1-00017-00001 CL 3mm_530_AIR_CL 3mm0.850.570.58 27  
STT-M-1-00018-00001 Starphire 3mm_530_AIR_Starphire 3mm0.850.600.59 27  
STT-M-1-00019-00001 LowE 366 3mm_530_AIR_CL 3mm0.800.210.46 28  
STT-M-1-00020-00001 LowE 366 3mm_530_AIR_i89 3mm0.780.200.45 27  
STT-M-1-00021-00001 Climaguard 70/36 3mm_530_AIR_CL 3mm0.800.280.49 28  
STT-M-1-00022-00001 Climaguard 62/27 3mm_530_AIR_CL 3mm0.800.210.44 28  
STT-M-1-00023-00001 CL 3mm_530_ARG_CL 3mm0.510.700.72 37 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , CL, No Grid
STT-M-1-00024-00001 Starphire 3mm_530_ARG_Starphire 3mm0.510.740.74 37 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , CL, No Grid
STT-M-1-00025-00001 LowE 366 3mm_530_ARG_CL 3mm0.330.250.57 38 Steel (Non thermally-broken)/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
12345678910...>>
Key:
Click the colum headers to sort the data acording to the column header.
A dash “-” in a rating column (SHGC / VT) indicates that there are no NFRC certified values for that individual product.
 

Copyright ©  National Fenestration Rating Council Incorporated ("NFRC") All rights reserved. NFRC's CMA data is protected by copyright. By accessing and downloading NFRC data from this webpage, the user agrees to abide by the Terms of Use.

The website is optimized for current browsers.

 

DISCLAIMER OF LIABILITY:
In no event shall the NFRC be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or any other loss) arising out of the use of this website or the information obtained from it, whether incidental or consequential. This provision shall apply even if the NFRC has been advised of the possibility of such damages.