CPD #Manufacturer Product CodeU-factorSHGCVTCondensation ResistanceProduct Description
CMI-M-58-00097-00001 1/8 clr-AIR-1/8 clr0.550.730.76 30 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , CL, No Grid
CMI-M-58-00097-00002 1/8 clr-AIR-1/8 clr0.550.730.76 30 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , CL, No Grid
CMI-M-58-00098-00001 5/32 clr-AIR-5/32 clr0.560.720.76 29 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , CL, No Grid
CMI-M-58-00098-00002 5/32 clr-AIR-5/32 clr0.560.720.76 29 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , CL, No Grid
CMI-M-58-00099-00001 3/16 clr-AIR-3/16 clr0.580.710.75 29 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , CL, No Grid
CMI-M-58-00099-00002 3/16 clr-AIR-3/16 clr0.580.710.75 29 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , CL, No Grid
CMI-M-58-00100-00001 1/8 clr-ARG-1/8 clr0.520.730.76 30 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: ARG/AIR(90/10) , CL, No Grid
CMI-M-58-00100-00002 1/8 clr-ARG-1/8 clr0.520.730.76 30 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: ARG/AIR(90/10) , CL, No Grid
CMI-M-58-00101-00001 5/32 clr-ARG-5/32 clr0.530.720.76 30 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: ARG/AIR(90/10) , CL, No Grid
CMI-M-58-00101-00002 5/32 clr-ARG-5/32 clr0.530.720.76 30 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: ARG/AIR(90/10) , CL, No Grid
CMI-M-58-00102-00001 3/16 clr-ARG-3/16 clr0.550.710.75 29 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: ARG/AIR(90/10) , CL, No Grid
CMI-M-58-00102-00002 3/16 clr-ARG-3/16 clr0.550.710.75 29 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: ARG/AIR(90/10) , CL, No Grid
CMI-M-58-00103-00001 1/8 CS28 clr-AIR-1/8 clr0.380.270.59 31 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
CMI-M-58-00103-00002 1/8 CS28 clr-AIR-1/8 clr0.380.270.59 31 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
CMI-M-58-00104-00001 1/8 clr-AIR-1/8 CS28 clr0.380.350.59 31 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
CMI-M-58-00104-00002 1/8 clr-AIR-1/8 CS28 clr0.380.350.59 31 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
CMI-M-58-00105-00001 5/32 CS28 clr-AIR-5/32 clr0.410.270.58 31 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
CMI-M-58-00105-00002 5/32 CS28 clr-AIR-5/32 clr0.410.270.58 31 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
CMI-M-58-00106-00001 5/32 clr-AIR-5/32 CS28 clr0.410.350.58 31 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
CMI-M-58-00106-00002 5/32 clr-AIR-5/32 CS28 clr0.410.350.58 31 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
CMI-M-58-00107-00001 3/16 CS28 clr-AIR-3/16 clr0.460.280.58 31 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
CMI-M-58-00107-00002 3/16 CS28 clr-AIR-3/16 clr0.460.280.58 31 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
CMI-M-58-00108-00001 3/16 clr-AIR-3/16 CS28 clr0.460.350.58 30 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
CMI-M-58-00108-00002 3/16 clr-AIR-3/16 CS28 clr0.460.350.58 30 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: AIR(100) , LowE, CL, No Grid
CMI-M-58-00109-00001 1/8 CS28 - ARG - 1/8 clr0.330.270.59 32 Aluminum w/ Thermal Breaks/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid
12345
Key:
Click the colum headers to sort the data acording to the column header.
A dash “-” in a rating column (SHGC / VT) indicates that there are no NFRC certified values for that individual product.
 

Copyright ©  National Fenestration Rating Council Incorporated ("NFRC") All rights reserved. NFRC's CMA data is protected by copyright. By accessing and downloading NFRC data from this webpage, the user agrees to abide by the Terms of Use.

The website is optimized for current browsers.

 

DISCLAIMER OF LIABILITY:
In no event shall the NFRC be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or any other loss) arising out of the use of this website or the information obtained from it, whether incidental or consequential. This provision shall apply even if the NFRC has been advised of the possibility of such damages.