TCW-K-10-00101-00001
| With & Without SDLs 2 mm ClimaGuard 55/27/ARG/2.3 mm Clear | 0.28 | 0.22 | 0.43 |
61
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
TCW-K-10-00101-00002
| With & Without SDLs 2 mm ClimaGuard 55/27/ARG/2.3 mm Clear | 0.28 | 0.20 | 0.38 |
61
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00101-00003
| 2 mm ClimaGuard 55/27/ARG/2.3 mm Clear | 0.28 | 0.20 | 0.38 |
61
| Vinyl/Not Applicable, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00102-00001
| With & Without SDLs 2 mm ClimaGuard 62/27/ARG/2.3 mm Clear | 0.28 | 0.20 | 0.47 |
61
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
TCW-K-10-00102-00002
| With & Without SDLs 2 mm ClimaGuard 62/27/ARG/2.3 mm Clear | 0.28 | 0.18 | 0.42 |
61
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00102-00003
| 2 mm ClimaGuard 62/27/ARG/2.3 mm Clear | 0.28 | 0.18 | 0.42 |
61
| Vinyl/Not Applicable, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00104-00001
| With & Without SDLs 3 mm ClimaGuard 55/27/ARG/3 mm Clear | 0.28 | 0.22 | 0.43 |
61
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
TCW-K-10-00104-00002
| With & Without SDLs 3 mm ClimaGuard 55/27/ARG/3 mm Clear | 0.28 | 0.20 | 0.38 |
61
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00104-00003
| 3 mm ClimaGuard 55/27/ARG/3 mm Clear | 0.28 | 0.20 | 0.38 |
61
| Vinyl/Not Applicable, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00105-00001
| With & Without SDLs 3 mm ClimaGuard 62/27/ARG/3 mm Clear | 0.28 | 0.20 | 0.47 |
61
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
TCW-K-10-00105-00002
| With & Without SDLs 3 mm ClimaGuard 62/27/ARG/3 mm Clear | 0.28 | 0.18 | 0.42 |
61
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00105-00003
| 3 mm ClimaGuard 62/27/ARG/3 mm Clear | 0.28 | 0.18 | 0.42 |
61
| Vinyl/Not Applicable, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00107-00001
| With & Without SDLs 3 mm ClimaGuard 55/27/ARG/5 mm Clear | 0.28 | 0.21 | 0.42 |
60
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
TCW-K-10-00107-00002
| With & Without SDLs 3 mm ClimaGuard 55/27/ARG/5 mm Clear | 0.28 | 0.19 | 0.38 |
60
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00107-00003
| 3 mm ClimaGuard 55/27/ARG/5 mm Clear | 0.28 | 0.19 | 0.38 |
60
| Vinyl/Not Applicable, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00108-00001
| With & Without SDLs 3 mm ClimaGuard 62/27/ARG/5 mm Clear | 0.28 | 0.20 | 0.47 |
60
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
TCW-K-10-00108-00002
| With & Without SDLs 3 mm ClimaGuard 62/27/ARG/5 mm Clear | 0.28 | 0.18 | 0.42 |
60
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00108-00003
| 3 mm ClimaGuard 62/27/ARG/5 mm Clear | 0.28 | 0.18 | 0.42 |
60
| Vinyl/Not Applicable, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00109-00001
| With & Without SDLs 2 mm ClimaGuard 70/36/ARG/2.3 mm Clear/ARG/2 mm ClimaGuard 70/36 | 0.20 | 0.26 | 0.42 |
68
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , Fill 2: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
TCW-K-10-00109-00002
| With & Without SDLs 2 mm ClimaGuard 70/36/ARG/2.3 mm Clear/ARG/2 mm ClimaGuard 70/36 | 0.20 | 0.23 | 0.38 |
68
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , Fill 2: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00109-00003
| 2 mm ClimaGuard 70/36/ARG/2.3 mm Clear/ARG/2 mm ClimaGuard 70/36 | 0.20 | 0.23 | 0.38 |
68
| Vinyl/Not Applicable, Fill 1: ARG(90/10) , Fill 2: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00111-00001
| With & Without SDLs 2 mm ClimaGuard 55/27/ARG/2.3 mm Clear | 0.27 | 0.22 | 0.43 |
63
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
TCW-K-10-00111-00002
| With & Without SDLs 2 mm ClimaGuard 55/27/ARG/2.3 mm Clear | 0.27 | 0.20 | 0.38 |
63
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00111-00003
| 2 mm ClimaGuard 55/27/ARG/2.3 mm Clear | 0.27 | 0.20 | 0.38 |
63
| Vinyl/Not Applicable, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
TCW-K-10-00112-00001
| With & Without SDLs 2 mm ClimaGuard 62/27/ARG/2.3 mm Clear | 0.27 | 0.20 | 0.47 |
63
| Vinyl/Not Applicable, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
|