DRU-K-28-00003-00001
| MB79N: CGPrem2/ARG90/ExtraClr/ARG90/CGPrem2 (4mm/4mm/4mm) 40mm IG | 0.19 | 0.35 | 0.49 |
75
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , Fill 2: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00004-00001
| MB79N: CGPrem2/ARG90/ExtraClr/ARG90/CGPrem2 (4mm/4mm/4mm) 48mm IG | 0.19 | 0.35 | 0.49 |
74
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , Fill 2: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00005-00001
| MB79N: CGPrem2/ARG90/ExtraClr/ARG90/CGPrem2 (6mm/4mm/6mm) 44mm IG | 0.18 | 0.34 | 0.49 |
74
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , Fill 2: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00008-00001
| MB79N: LamiXN/ARG90/PlaniClear/ARG90/LamiXN (3mm|038PVB|3mm/4mm/3mm|038PVB|3mm) 40mm IG | 0.19 | 0.33 | 0.49 |
74
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , Fill 2: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00009-00001
| MB79N: LamiCGPrem2/ARG90/ExtraClr/ARG90/LamiCGPrem2 (4mm|076PVB|4mm/4mm/4mm|076PVB|4mm) 48mm IG | 0.18 | 0.32 | 0.48 |
74
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , Fill 2: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00010-00001
| MB79N: SN63/ARG90/ExtraClr (6mm/4mm) 24mm IG | 0.31 | 0.22 | 0.42 |
59
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: AIR(100) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00013-00001
| MB86N: CGPrem2/ARG90/ExtraClr/ARG90/CGPrem2 (4mm/4mm/4mm) 40mm IG | 0.18 | 0.35 | 0.49 |
80
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , Fill 2: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00014-00001
| MB86N: CGPrem2/ARG90/ExtraClr/ARG90/CGPrem2 (4mm/4mm/4mm) 48mm IG | 0.18 | 0.35 | 0.49 |
80
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , Fill 2: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00015-00001
| MB86N: CGPrem2/ARG90/ExtraClr/ARG90/CGPrem2 (6mm/4mm/6mm) 44mm IG | 0.17 | 0.34 | 0.49 |
79
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , Fill 2: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00018-00001
| MB86N: LamiXN/ARG90/PlaniClear/ARG90/LamiXN (3mm|038PVB|3mm/4mm/3mm|038PVB|3mm) 40mm IG | 0.18 | 0.33 | 0.49 |
78
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , Fill 2: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00019-00001
| MB86N: LamiCGPrem2/ARG90/ExtraClr/ARG90/LamiCGPrem2 (4mm|076PVB|4mm/4mm/4mm|076PVB|4mm) 48mm IG | 0.17 | 0.32 | 0.48 |
80
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , Fill 2: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00020-00001
| MB86N: SN63/ARG90/ExtraClr (6mm/4mm) 24mm IG | 0.30 | 0.22 | 0.42 |
59
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: AIR(100) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00326-00001
| MB79N: CGP 2 / AIR / Extra CLR / AIR / CGP 2 (4mm/4mm/4mm) - 40mm IG - WarmEdge spacer - No Grid | 0.22 | 0.35 | 0.49 |
70
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: AIR(100) , Fill 2: AIR(100) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00327-00001
| MB79N: CGP 2 / AIR / Extra CLR / AIR / CGP 2 (4mm/4mm/4mm) - 48mm IG - WarmEdge spacer - No Grid | 0.22 | 0.35 | 0.49 |
68
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: AIR(100) , Fill 2: AIR(100) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00328-00001
| MB79N: CGP 2 / AIR / Extra CLR / AIR / CGP 2 (6mm/4mm/6mm) - 44mm IG - WarmEdge spacer - No Grid | 0.22 | 0.34 | 0.49 |
69
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: AIR(100) , Fill 2: AIR(100) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00329-00001
| MB79N: SGG Planitherm XN / AIR / SGG Planiclear / AIR / SGG Planitherm XN (3mm|1x015PVB|3mm/4mm/3mm|1x015PVB|3mm) - 40.8mm IG - WarmEdge spacer - No Grid | 0.23 | 0.34 | 0.49 |
69
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: AIR(100) , Fill 2: AIR(100) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00330-00001
| MB79N: CGP 2 Lami / AIR / Extra CLR / AIR / CGP 2 Lami (4mm|2x015PVB|4mm/4mm/4mm|2x015PVB|4mm) - 48mm IG - WarmEdge spacer - No Grid | 0.22 | 0.33 | 0.48 |
68
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: AIR(100) , Fill 2: AIR(100) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00333-00001
| MB79N: SGG CL XTM 61-29 / ARG90 / CGP 2 (6mm/4mm) - 26mm IG - WarmEdge spacer - No Grid | 0.30 | 0.18 | 0.41 |
64
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00335-00001
| MB79N: SN 63 / ARG90 / CGP 2 (6mm/4mm) - 24mm IG - WarmEdge spacer - No Grid | 0.29 | 0.21 | 0.42 |
62
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00336-00001
| MB79N: SN 63 / AIR / CGP 2 (6mm/4mm) - 24mm IG - WarmEdge spacer - No Grid | 0.32 | 0.22 | 0.42 |
58
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: AIR(100) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00337-00001
| MB79N: SN 63 / ARG90 / CGP 2 (6mm/6mm) - 26mm IG - WarmEdge spacer - No Grid | 0.29 | 0.21 | 0.41 |
62
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00338-00001
| MB79N: SN 63 / AIR / CGP 2 (6mm/6mm) - 26mm IG - WarmEdge spacer - No Grid | 0.32 | 0.22 | 0.41 |
58
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: AIR(100) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00339-00001
| MB79N: SN 63 / ARG90 / Extra CLR (6mm/6mm) - 26mm IG - WarmEdge spacer - No Grid | 0.30 | 0.21 | 0.42 |
61
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00341-00001
| MB79N: SGG CL SKN 176 / ARG90 / CGP 2 (6mm/4mm) - 24mm IG - WarmEdge spacer - No Grid | 0.29 | 0.23 | 0.47 |
62
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
DRU-K-28-00343-00001
| MB79N: SGG CL SKN 176 / ARG90 / Extra CLR (6mm/4mm) - 24mm IG - WarmEdge spacer - No Grid | 0.30 | 0.23 | 0.47 |
61
| Aluminum w/ Thermal Breaks/Aluminum w/ Thermal Breaks, Fill 1: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
|