CWL-K-28-00073-00001
| E270/ARG90/CLR (6MM/6MM) 25MM IG | 0.23 | 0.25 | 0.48 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00073-00002
| E270/ARG90/CLR (6MM/6MM) 25MM IG | 0.23 | 0.22 | 0.41 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00073-00003
| E270/ARG90/CLR (6MM/6MM) 25MM IG | 0.23 | 0.20 | 0.36 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00074-00001
| E366/ARG90/CLR (6MM/6MM) 25MM IG | 0.23 | 0.19 | 0.44 |
60
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00074-00002
| E366/ARG90/CLR (6MM/6MM) 25MM IG | 0.23 | 0.17 | 0.39 |
60
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00074-00003
| E366/ARG90/CLR (6MM/6MM) 25MM IG | 0.23 | 0.15 | 0.33 |
60
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00075-00001
| E340/ARG90/CLR (6MM/6MM) 25MM IG | 0.23 | 0.13 | 0.27 |
60
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00075-00002
| E340/ARG90/CLR (6MM/6MM) 25MM IG | 0.23 | 0.12 | 0.23 |
60
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00075-00003
| E340/ARG90/CLR (6MM/6MM) 25MM IG | 0.23 | 0.10 | 0.20 |
60
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00076-00002
| E180/ARG90/CLR (6MM/6MM) 25MM IG | 0.24 | 0.38 | 0.47 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00076-00003
| E180/ARG90/CLR (6MM/6MM) 25MM IG | 0.24 | 0.33 | 0.40 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00077-00001
| E270/ARG90/i89 (6MM/6MM) 25MM IG | 0.20 | 0.25 | 0.47 |
49
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00077-00002
| E270/ARG90/i89 (6MM/6MM) 25MM IG | 0.20 | 0.22 | 0.40 |
49
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00077-00003
| E270/ARG90/i89 (6MM/6MM) 25MM IG | 0.20 | 0.19 | 0.35 |
49
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00078-00001
| E366/ARG90/i89 (6MM/6MM) 25MM IG | 0.19 | 0.19 | 0.43 |
50
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00078-00002
| E366/ARG90/i89 (6MM/6MM) 25MM IG | 0.19 | 0.17 | 0.38 |
50
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00078-00003
| E366/ARG90/i89 (6MM/6MM) 25MM IG | 0.19 | 0.15 | 0.32 |
50
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00079-00001
| E340/ARG90/i89 (6MM/6MM) 25MM IG | 0.20 | 0.13 | 0.26 |
49
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00079-00002
| E340/ARG90/i89 (6MM/6MM) 25MM IG | 0.20 | 0.11 | 0.23 |
49
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00079-00003
| E340/ARG90/i89 (6MM/6MM) 25MM IG | 0.20 | 0.10 | 0.19 |
49
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00080-00002
| E180/ARG90/i89 (6MM/6MM) 25MM IG | 0.20 | 0.37 | 0.46 |
48
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00080-00003
| E180/ARG90/i89 (6MM/6MM) 25MM IG | 0.20 | 0.32 | 0.39 |
48
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00081-00001
| E270/AIR/CLR (6MM/6MM) 25MM IG | 0.26 | 0.26 | 0.48 |
56
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: AIR(100) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00081-00002
| E270/AIR/CLR (6MM/6MM) 25MM IG | 0.26 | 0.23 | 0.41 |
56
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: AIR(100) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00081-00003
| E270/AIR/CLR (6MM/6MM) 25MM IG | 0.26 | 0.20 | 0.36 |
56
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: AIR(100) , LowE, CL, Grid |
|
|
|
|
|