CWL-K-28-00001-00003
| E272/ Air / Clear (6mm) 25|4mm | 0.27 | 0.22 | 0.37 |
56
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: AIR(100) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00002-00001
| E272/ Argon / Clear (6mm) 25|4mm | 0.24 | 0.29 | 0.49 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00002-00002
| E272/ Argon / Clear (6mm) 25|4mm | 0.24 | 0.25 | 0.43 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00002-00003
| E272/ Argon / Clear (6mm) 25|4mm | 0.24 | 0.22 | 0.37 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00003-00001
| E270/ Argon / Clear (6mm) 25|4mm | 0.23 | 0.25 | 0.48 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00003-00002
| E270/ Argon / Clear (6mm) 25|4mm | 0.23 | 0.22 | 0.42 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00003-00003
| E270/ Argon / Clear (6mm) 25|4mm | 0.23 | 0.20 | 0.36 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00004-00001
| E366/ Argon / Clear (6mm) 25|4mm | 0.23 | 0.19 | 0.44 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00004-00002
| E366/ Argon / Clear (6mm) 25|4mm | 0.23 | 0.17 | 0.39 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00004-00003
| E366/ Argon / Clear (6mm) 25|4mm | 0.23 | 0.15 | 0.33 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00005-00001
| E340/ Argon / Clear (6mm) 25|4mm | 0.23 | 0.13 | 0.27 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00005-00002
| E340/ Argon / Clear (6mm) 25|4mm | 0.23 | 0.12 | 0.23 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00005-00003
| E340/ Argon / Clear (6mm) 25|4mm | 0.23 | 0.10 | 0.20 |
59
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00006-00002
| Clear/ Argon / E180 (6mm) 25|4mm | 0.24 | 0.40 | 0.47 |
58
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00006-00003
| Clear/ Argon / E180 (6mm) 25|4mm | 0.24 | 0.35 | 0.41 |
58
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00007-00001
| E366/ Air/ Clear/ Air/ E180 (6mm) 44|0mm | 0.17 | 0.17 | 0.38 |
72
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: AIR(100) , Fill 2: AIR(100) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00007-00002
| E366/ Air/ Clear/ Air/ E180 (6mm) 44|0mm | 0.17 | 0.16 | 0.33 |
72
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: AIR(100) , Fill 2: AIR(100) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00007-00003
| E366/ Air/ Clear/ Air/ E180 (6mm) 44|0mm | 0.17 | 0.14 | 0.29 |
72
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: AIR(100) , Fill 2: AIR(100) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00008-00001
| E180/ Arg/ Clear/ Arg/ E180 (6mm) 44|0mm | 0.15 | 0.37 | 0.47 |
74
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , Fill 2: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00008-00002
| E180/ Arg/ Clear/ Arg/ E180 (6mm) 44|0mm | 0.15 | 0.32 | 0.41 |
74
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , Fill 2: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00008-00003
| E180/ Arg/ Clear/ Arg/ E180 (6mm) 44|0mm | 0.15 | 0.28 | 0.35 |
74
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , Fill 2: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00009-00001
| E272/ Arg/ Clear/ Arg/ E180 (6mm) 44|0mm | 0.15 | 0.25 | 0.43 |
75
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , Fill 2: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
CWL-K-28-00009-00002
| E272/ Arg/ Clear/ Arg/ E180 (6mm) 44|0mm | 0.15 | 0.22 | 0.37 |
75
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , Fill 2: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00009-00003
| E272/ Arg/ Clear/ Arg/ E180 (6mm) 44|0mm | 0.15 | 0.19 | 0.32 |
75
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , Fill 2: ARG/AIR(90/10) , LowE, CL, Grid |
|
|
|
|
CWL-K-28-00010-00001
| E270/ Arg/ Clear/ Arg/ E180 (6mm) 44|0mm | 0.15 | 0.23 | 0.42 |
75
| Fiberglass w/ foam-filled insulation/Fiberglass w/ foam-filled insulation, Fill 1: ARG/AIR(90/10) , Fill 2: ARG/AIR(90/10) , LowE, CL, No Grid |
|
|
|
|
|